Capacity at 100% duty cykle: 48 kW
Primary Voltage: 3 x 400 V / 50 Hz
Primary Current: 3 x 73 A
Primary Cable Dimension: 5 x 25 mm2
Output Voltage: 0 - 42 - 84 V
Output Circuit Quantity: 6
Output Voltage and Current of one circuit: 42 V - 100 A, 84 V - 100 A
Heating Elements Quantity of one circuit (1 heating element - 4 kW): 2
PID Temperature Controller Qty: 3
Controlled Curcuits Quantity: 6
Temperature Range: 0 - 1200 °C
Temperature Record: 6-reentrant printer with graphic recording
HTU Dimensions (width, depth, height): 880, 735, 1 280 mm
HTU total weight: 450 kg
Modification of offered Heat Treatment Units are available according to customer requirements.